Fertilisers & substrates 5 min read

Measuring pH and EC: guide values, calibration and care

Which pH for soil, coco and hydro? Which EC in which phase? With guide value tables, ppm conversion, the right order when mixing and step-by-step calibration.

The pH value shows how acidic or alkaline your irrigation water or nutrient solution is, the EC value how many dissolved nutrient salts it contains. As guide values, soil takes a pH of 6.0 to 7.0, coco and hydroponics 5.5 to 6.5. Depending on the phase, EC lies roughly between 0.4 mS/cm for young plants and about 2.0 mS/cm during flowering. Measure after mixing: first add fertiliser to the water, then adjust the pH. A pH meter must be calibrated regularly with buffer solution, otherwise it measures inaccurately.

What do pH and EC tell you?

The pH value determines how well the roots can take up nutrients. If it is outside the suitable range, deficiency symptoms can appear even though there is enough fertiliser in the water. Many apparent nutrient problems are in fact a wrong pH.

The EC value (electrical conductivity) measures the amount of dissolved salts and thus the fertiliser strength. It does not say which nutrients are present, only how many in total. Too low means: too little food. Too high means: too many salts in the substrate, and the plant can take up water less easily.

Which pH and EC values are right?

The values depend on the substrate and the phase. Soil buffers the pH more strongly, so the range there is wider. Coco and hydroponics react faster and need a slightly lower pH.

SubstratepH rangeOptimal
Soil6.0 to 7.0around 6.2 to 6.8
Coco5.5 to 6.5around 5.8 to 6.2
Hydroponics and deep water culture5.5 to 6.5around 5.8 to 6.2
PhaseEC (mS/cm)ppm (500 scale)ppm (700 scale)
Seedlings, young plants0.4 to 0.8200 to 400280 to 560
Vegetative growth0.8 to 1.6400 to 800560 to 1,120
Flowering1.4 to 2.2700 to 1,100980 to 1,540
Last days before harvest0.4 to 0.6200 to 300280 to 420

The ranges are summarised from several sources that differ in details. For hydroponics, some manufacturers state slightly lower values for vegetative growth. When in doubt, follow your manufacturer's feeding schedule and work your way up from low values.

For conversion: some devices show ppm instead of EC. On the 500 scale, 1.0 mS/cm equals 500 ppm; on the 700 scale, it equals 700 ppm. So when comparing with tables, check which scale is meant. The CF value is EC times 10.

How do I measure correctly?

Measure the finished nutrient solution, not just the tap water. The order matters because fertiliser shifts the pH.

  1. Measure the source water: Note the pH and EC of the tap water once. The EC of the water is the base to which the fertiliser is added.
  2. Mix in fertiliser: Dose according to the schedule and stir well.
  3. Measure EC: Is the fertiliser strength right? If not, dilute with water or add a little more fertiliser.
  4. Measure and adjust pH: Only now correct with pH down or pH up in small steps, stir, wait briefly and measure again.
  5. Mind the temperature: Many devices compensate for temperature automatically. Still, measure at a similar water temperature so that readings stay comparable.

Suitable for adjusting are, for example, Canna pH- Grow and Canna pH- Bloom or the organic Biobizz Bio·Down pH- and Bio·Up pH+. Only ever add a few drops at a time, as these products are strong.

The runoff water gives an additional clue: water so much that some drains out of the bottom of the pot, and measure this runoff. If its EC is clearly above that of the irrigation solution, salts are building up in the substrate. Then water with plainer water or a weaker solution.

Meter, test strips or drop test?

For getting started and for checks, a drop test such as the Terra Aquatica pH test kit is enough: inexpensive, no calibration, but only accurate to colour steps. If you mix regularly, a digital device serves you better.

MethodAdvantagesDisadvantagesExamples
Drop testinexpensive, no calibrationcolour steps only, no ECTerra Aquatica pH test kit
pH penexact number, fastneeds calibration and carepH51, Milwaukee pH600, Bluelab pH Pen
Combined pH and EC meterboth values in one devicemore expensive, both probes need careBluelab Combo Meter, Milwaukee MW802 PRO, Bluelab OnePen
Measuring directly in the substratemeasures in the pot instead of in the solutionspecial probe requiredAqua Master Tools S300 Pro 3, E300 Pro2
Continuous monitormeasures around the clock, alarmfor hydroponics and larger setupsBluelab Guardian Wi-Fi, Milwaukee MC811 MAX

How do I calibrate a pH meter?

Calibration uses two fresh buffer solutions, pH 7 and pH 4. Depending on the device, manufacturers recommend this at least once a month, more often with frequent use; Milwaukee advises weekly. Also calibrate after a longer break or when readings seem implausible.

  1. Clean the electrode: Rinse briefly and dab carefully, do not rub. Which water to rinse with is set out in your device's manual, as manufacturers handle this differently.
  2. pH 7 first: Dip the electrode into fresh pH 7 solution, start calibration and wait until the device confirms.
  3. Rinse: Rinse briefly so that no solution gets into the next one.
  4. pH 4: Dip into fresh pH 4 solution and confirm the second point.
  5. Dispose of the solutions: Do not pour used buffer solution back into the bottle, as it would then be contaminated.

You calibrate the EC value less often, with a suitable EC calibration solution, as specified in your device's manual.

How do I care for and store the electrode?

The pH electrode must always stay moist. Keep it in the protective cap with a few drops of storage solution (usually potassium chloride). The manufacturers agree on this: never store it in distilled, deionised or reverse osmosis water, as this permanently damages the electrode. If the electrode has dried out, soak it in storage solution according to the manufacturer's instructions and recalibrate afterwards.

Electrodes are wear parts and deteriorate over time: if the device reacts sluggishly or can no longer be calibrated, the probe is worn out. On some devices only the probe can be replaced, for example on the Bluelab pH PenPlus or with the Milwaukee SE600 replacement electrode for the MW802.

Common mistakes: what often goes wrong when measuring?

  • pH adjusted before the fertiliser: The fertiliser shifts the pH again. First fertiliser, then pH.
  • Never calibrated: An inaccurate device shows wrong values and you correct in the wrong direction.
  • Electrode stored dry or in distilled water: It becomes sluggish and inaccurate or fails completely.
  • Too much pH down at once: The value overshoots the target. Work in small steps.
  • ppm scales confused: 1,000 ppm on the 500 scale is not the same as 1,000 ppm on the 700 scale.
  • Only fed by schedule, never measured: Depending on tap water and substrate, the same fertiliser can give very different values.

In our shop at Lorenzstraße 9 in Hof, we can show you the meters from Milwaukee, Bluelab and Aqua Master Tools and explain calibration directly on the device. You will find all devices online under Measuring technology, fertilisers and pH regulators under Fertiliser & substrates.

Featured in this guide

Frequently asked questions

How often do I need to calibrate my pH meter?

Depending on the manufacturer, at least once a month, more often with frequent use; Milwaukee recommends weekly. Also calibrate after a longer break and whenever the readings seem implausible. Use fresh pH 7 and pH 4 buffer solutions for this.

Can I store the pH electrode in distilled water?

No. The manufacturers agree on this: distilled, deionised or reverse osmosis water damages the electrode. Keep it moist with a few drops of storage solution in the protective cap.

Do I adjust the pH first or add the fertiliser first?

First add the fertiliser to the water and check the EC, then adjust the pH. Fertiliser shifts the pH value, so correcting it beforehand would be wasted effort.

What does ppm on my EC meter mean?

ppm is a conversion of the EC value. On the 500 scale, 1.0 mS/cm equals 500 ppm; on the 700 scale, 700 ppm. Check the manual to see which scale your device uses before comparing readings with tables.

Is a drop test enough instead of a meter?

For occasional checks, yes. A drop test is inexpensive and needs no calibration, but it only shows colour steps and no EC. If you mix nutrient solution regularly, a digital meter measures more precisely.