The pH value shows how acidic or alkaline your irrigation water or nutrient solution is, the EC value how many dissolved nutrient salts it contains. As guide values, soil takes a pH of 6.0 to 7.0, coco and hydroponics 5.5 to 6.5. Depending on the phase, EC lies roughly between 0.4 mS/cm for young plants and about 2.0 mS/cm during flowering. Measure after mixing: first add fertiliser to the water, then adjust the pH. A pH meter must be calibrated regularly with buffer solution, otherwise it measures inaccurately.
What do pH and EC tell you?
The pH value determines how well the roots can take up nutrients. If it is outside the suitable range, deficiency symptoms can appear even though there is enough fertiliser in the water. Many apparent nutrient problems are in fact a wrong pH.
The EC value (electrical conductivity) measures the amount of dissolved salts and thus the fertiliser strength. It does not say which nutrients are present, only how many in total. Too low means: too little food. Too high means: too many salts in the substrate, and the plant can take up water less easily.
Which pH and EC values are right?
The values depend on the substrate and the phase. Soil buffers the pH more strongly, so the range there is wider. Coco and hydroponics react faster and need a slightly lower pH.
| Substrate | pH range | Optimal |
|---|---|---|
| Soil | 6.0 to 7.0 | around 6.2 to 6.8 |
| Coco | 5.5 to 6.5 | around 5.8 to 6.2 |
| Hydroponics and deep water culture | 5.5 to 6.5 | around 5.8 to 6.2 |
| Phase | EC (mS/cm) | ppm (500 scale) | ppm (700 scale) |
|---|---|---|---|
| Seedlings, young plants | 0.4 to 0.8 | 200 to 400 | 280 to 560 |
| Vegetative growth | 0.8 to 1.6 | 400 to 800 | 560 to 1,120 |
| Flowering | 1.4 to 2.2 | 700 to 1,100 | 980 to 1,540 |
| Last days before harvest | 0.4 to 0.6 | 200 to 300 | 280 to 420 |
The ranges are summarised from several sources that differ in details. For hydroponics, some manufacturers state slightly lower values for vegetative growth. When in doubt, follow your manufacturer's feeding schedule and work your way up from low values.
For conversion: some devices show ppm instead of EC. On the 500 scale, 1.0 mS/cm equals 500 ppm; on the 700 scale, it equals 700 ppm. So when comparing with tables, check which scale is meant. The CF value is EC times 10.
How do I measure correctly?
Measure the finished nutrient solution, not just the tap water. The order matters because fertiliser shifts the pH.
- Measure the source water: Note the pH and EC of the tap water once. The EC of the water is the base to which the fertiliser is added.
- Mix in fertiliser: Dose according to the schedule and stir well.
- Measure EC: Is the fertiliser strength right? If not, dilute with water or add a little more fertiliser.
- Measure and adjust pH: Only now correct with pH down or pH up in small steps, stir, wait briefly and measure again.
- Mind the temperature: Many devices compensate for temperature automatically. Still, measure at a similar water temperature so that readings stay comparable.
Suitable for adjusting are, for example, Canna pH- Grow and Canna pH- Bloom or the organic Biobizz Bio·Down pH- and Bio·Up pH+. Only ever add a few drops at a time, as these products are strong.
The runoff water gives an additional clue: water so much that some drains out of the bottom of the pot, and measure this runoff. If its EC is clearly above that of the irrigation solution, salts are building up in the substrate. Then water with plainer water or a weaker solution.
Meter, test strips or drop test?
For getting started and for checks, a drop test such as the Terra Aquatica pH test kit is enough: inexpensive, no calibration, but only accurate to colour steps. If you mix regularly, a digital device serves you better.
| Method | Advantages | Disadvantages | Examples |
|---|---|---|---|
| Drop test | inexpensive, no calibration | colour steps only, no EC | Terra Aquatica pH test kit |
| pH pen | exact number, fast | needs calibration and care | pH51, Milwaukee pH600, Bluelab pH Pen |
| Combined pH and EC meter | both values in one device | more expensive, both probes need care | Bluelab Combo Meter, Milwaukee MW802 PRO, Bluelab OnePen |
| Measuring directly in the substrate | measures in the pot instead of in the solution | special probe required | Aqua Master Tools S300 Pro 3, E300 Pro2 |
| Continuous monitor | measures around the clock, alarm | for hydroponics and larger setups | Bluelab Guardian Wi-Fi, Milwaukee MC811 MAX |
How do I calibrate a pH meter?
Calibration uses two fresh buffer solutions, pH 7 and pH 4. Depending on the device, manufacturers recommend this at least once a month, more often with frequent use; Milwaukee advises weekly. Also calibrate after a longer break or when readings seem implausible.
- Clean the electrode: Rinse briefly and dab carefully, do not rub. Which water to rinse with is set out in your device's manual, as manufacturers handle this differently.
- pH 7 first: Dip the electrode into fresh pH 7 solution, start calibration and wait until the device confirms.
- Rinse: Rinse briefly so that no solution gets into the next one.
- pH 4: Dip into fresh pH 4 solution and confirm the second point.
- Dispose of the solutions: Do not pour used buffer solution back into the bottle, as it would then be contaminated.
You calibrate the EC value less often, with a suitable EC calibration solution, as specified in your device's manual.
How do I care for and store the electrode?
The pH electrode must always stay moist. Keep it in the protective cap with a few drops of storage solution (usually potassium chloride). The manufacturers agree on this: never store it in distilled, deionised or reverse osmosis water, as this permanently damages the electrode. If the electrode has dried out, soak it in storage solution according to the manufacturer's instructions and recalibrate afterwards.
Electrodes are wear parts and deteriorate over time: if the device reacts sluggishly or can no longer be calibrated, the probe is worn out. On some devices only the probe can be replaced, for example on the Bluelab pH PenPlus or with the Milwaukee SE600 replacement electrode for the MW802.
Common mistakes: what often goes wrong when measuring?
- pH adjusted before the fertiliser: The fertiliser shifts the pH again. First fertiliser, then pH.
- Never calibrated: An inaccurate device shows wrong values and you correct in the wrong direction.
- Electrode stored dry or in distilled water: It becomes sluggish and inaccurate or fails completely.
- Too much pH down at once: The value overshoots the target. Work in small steps.
- ppm scales confused: 1,000 ppm on the 500 scale is not the same as 1,000 ppm on the 700 scale.
- Only fed by schedule, never measured: Depending on tap water and substrate, the same fertiliser can give very different values.
In our shop at Lorenzstraße 9 in Hof, we can show you the meters from Milwaukee, Bluelab and Aqua Master Tools and explain calibration directly on the device. You will find all devices online under Measuring technology, fertilisers and pH regulators under Fertiliser & substrates.