You clean a vaporizer in two stages: after every use you empty the chamber and brush the screen and chamber out dry. Regularly, a deep clean of the mouthpiece, cooling path and screens follows, either in warm soapy water or in isopropyl alcohol. The manufacturers set the intervals: for the Mighty+ cooling unit, Storz & Bickel specifies no later than 7 days after the last use, PAX every 3 to 5 sessions for the Flow. According to Storz & Bickel, plastic parts stay in isopropyl alcohol for no more than 30 minutes, and the housing and electronics never go into liquid. And before you switch it on again, every part must be completely dry.
Which parts of a vaporizer do I need to clean?
During vaporising, condensate settles wherever the vapour cools down. Depending on the device, these are mainly the following parts:
- Chamber (filling chamber, oven): Remnants of dry material and a thin film remain here. It is only brushed out and wiped with a slightly damp cotton bud, never flooded.
- Screens: They hold the material in the chamber and clog over time. A clogged screen makes the draw heavy.
- Cooling path and cooling unit: The route from the heating element to the mouth: with Storz & Bickel the removable cooling unit, with Arizer the glass mouthpiece, with DynaVap the condenser. This is where most condensate collects.
- Mouthpiece and seals: Mouthpieces can usually be removed. Sealing rings and O-rings ensure airtightness and wear out.
How often should I clean my vaporizer?
There is no uniform interval; the manufacturers give different values. The table summarises what the manufacturers themselves state:
| Manufacturer / device | After every use | Deep clean according to manufacturer | Cleaning agent according to manufacturer |
|---|---|---|---|
| Storz & Bickel Mighty+ | Clean the filling chamber screen and the cooling unit screen with the cleaning brush, check the cooling unit | Cooling unit no later than 7 days after the last use and when deposits are visible | Warm soapy water (soak for at least 5 minutes) or isopropyl alcohol (max. 30 minutes) |
| PAX Flow | Empty the chamber with the multi-tool | Every 3 to 5 sessions | Isopropyl alcohol: cotton buds for oven and air path, soak the screen for 15 minutes |
| Arizer (Solo, Air, ArGo) | Shake out the chamber, empty the glass parts | No fixed figure, glass parts as needed | Glass parts at least 30 minutes in 99 per cent isopropyl alcohol |
| DynaVap | Brush out the tip and screen | With frequent use every 1 to 2 weeks, otherwise about monthly | Isopropyl alcohol from 90 %, soak metal parts for 15 to 30 minutes |
The figures only apply to the respective device; your instructions for use are what count. Rule of thumb: if the draw gets heavier or deposits are visible in the cooling unit, a deep clean is due, even if the interval has not yet been reached.
Isopropyl alcohol or soapy water: what is best for cleaning?
Isopropyl alcohol dissolves condensate quickly and evaporates with little residue. The manufacturers recommend high concentrations: Arizer gives 99 %, DynaVap at least 90 %. Storz & Bickel allows both, warm soapy water and isopropyl alcohol. For plastic parts, soapy water is the more cautious choice, because according to Storz & Bickel alcohol can make them brittle with prolonged contact.
- Isopropyl alcohol: For glass, stainless steel and the cooling unit. Isopropyl alcohol is highly flammable, so only work on the cold device, away from flames and in a well-ventilated room.
- Warm soapy water: For plastic parts, mouthpieces and anything delicate. Then rinse thoroughly with clean water.
- Cotton buds: For the chamber and oven. Only moisten them slightly so that nothing runs into the device.
- Pipe cleaners and wire brush: For narrow air paths. PAX recommends them for the vapour path, DynaVap for the inside of the condenser.
- Cleaning brush: For the daily dry cleaning of the chamber and screens, usually included in the scope of delivery or in the wear parts set.
How do I clean the chamber, screens and cooling path step by step?
The procedure is the same for most devices. It is based on the instructions from Storz & Bickel, PAX and DynaVap:
- Let it cool down: Switch the device off and let it cool down completely. PAX gives about 10 minutes for the Flow. Unplug the charging cable.
- Take apart: Remove the mouthpiece, cooling unit or glass part and push out the screens with the filling chamber tool. Pull off the sealing rings and O-rings and note where they sit.
- Clean the chamber dry: Loosen remnants with the brush and carefully tap the device out with the opening facing down.
- Wipe the chamber damp: Dip a cotton bud lightly in isopropyl alcohol, squeeze it out and wipe the chamber walls. Nothing should drip.
- Soak the parts: Place the cooling unit, screens, glass or metal parts in isopropyl alcohol or warm soapy water. Plastic parts no more than 30 minutes in isopropyl alcohol.
- Clear the air paths: Run a pipe cleaner or wire brush through the cooling path and mouthpiece until they are clean.
- Rinse: Rinse all parts under running water; Storz & Bickel specifies at least one minute. This also removes any alcohol residue.
- Inspect: Check the parts for cracks, hardening, brittleness or discolouration and discard damaged parts.
- Dry and reassemble: Let everything dry completely, insert the screens with the curved side facing up and make sure the sealing rings sit correctly.
PAX recommends heating the device up empty once after reassembly, switching it off again and letting it cool. For portable devices, Arizer advises loosening residue with the stirring tool after heating up on the highest setting and shaking out the cooled device.
Which parts must not go into alcohol?
The manufacturers differ markedly here. What is permitted for one device can cause damage to another:
- Housing, electronics and USB-C cable: Never immerse in water or alcohol and do not clean with a water or steam jet. Only wipe dry or with a slightly damp soft cloth.
- Oven lid on PAX: PAX expressly states that the oven lid must never be immersed in liquid. It is only wiped with a cotton bud.
- Cap on DynaVap: Do not soak it; clean it with a cotton bud or small brush.
- O-rings and seals: DynaVap advises removing O-rings before soaking and not putting them in alcohol, because the material suffers. Storz & Bickel, on the other hand, allows all parts of the cooling unit, including the sealing rings, to be placed in isopropyl alcohol for up to 30 minutes. Follow your device's instructions; if in doubt, only wipe the seals.
- Lid latch with hologram on Storz & Bickel: Only wipe it, otherwise the sticker fades and the adhesive comes loose.
- Hot glass: Arizer warns against placing hot glass parts in cold water. Let them cool down first.
When do I replace screens, seals and mouthpieces?
Screens, sealing rings, mouthpieces and cooling units are wear parts. Replace them when a screen is bent or permanently clogged, a seal has become cracked or hard, or a plastic part seems brittle after cleaning. When reinserting, Storz & Bickel expressly provides for bending the cleaned screen into shape beforehand or simply using a new one.
- Storz & Bickel: The wear parts set for the Mighty+ contains mouthpieces, a cooling unit, screens, filling chamber tools and a brush. Also suitable are the Mighty+ cooling units in a pack of three, the wear parts set for the Venty and the wear parts set for the Veazy with sealing rings and screens.
- Arizer: 50 original replacement screens for the Air Max and Solo 2.
- DynaVap: The DynaKit Basic with screens, O-rings and cotton pipe cleaners.
- Smono: for example the wear parts set for the Smono 3.
Common mistakes: what often goes wrong when cleaning a vaporizer?
- Device immersed or held under the tap: Liquid in the electronics can permanently damage the device. Only the removable parts go in the bath.
- Cotton bud too wet: Isopropyl alcohol runs into the device. Always squeeze out the cotton bud before it goes into the chamber.
- Plastic in alcohol overnight: Parts become brittle or discoloured. With Storz & Bickel, no more than 30 minutes.
- Assembled damp: Residual moisture or alcohol in the cooling path does not belong in the hot device. Better to let it dry for longer.
- No rinsing: Alcohol residue remains in the cooling unit. Always rinse with clean water after soaking.
- Screen forgotten or inserted incorrectly: Without a correctly seated screen, particles get into the cooling unit and clog it.
In our shop at Lorenzstraße 9 in Hof we are happy to show you how your device can be taken apart, and we have screens, seals and cooling units for Storz & Bickel, Arizer and DynaVap in stock. Online you will find everything under Vaporizer accessories, specifically for Storz & Bickel under Storz & Bickel accessories and for Arizer under Arizer accessories.